W83793G Datasheet, PDF (71/131 Pages) Winbond – Winbond H/W Monitor
W83793G
Continued.
BIT
DESCRIPTION
Fan5(Enable Fan5 Smart Fan).
4
0: Fan5 has no relation with this temperature source.
1: Applies SmartFan control on Fan5 and this temperature.
Fan4(Enable Fan4 Smart Fan).
3
0: Fan4 has no relation with this temperature source.
1: Applies SmartFan control on Fan4 and this temperature.
Fan3(Enable Fan3 Smart Fan).
2
0: Fan3 has no relation with this temperature source.
1: Applies SmartFan control on Fan3 and this temperature.
Fan2(Enable Fan2 Smart Fan).
1
0: Fan2 has no relation with this temperature source.
1: Applies SmartFan control on Fan2 and this temperature.
Fan1(Enable Fan1 Smart Fan).
0 0: Fan1 has no relation with this temperature source.
1: Applies SmartFan control on Fan1 and this temperature.
Here using an example to explain the concept of TempFanSelect Mapping. Considering this case,
TD1FanSelect is set to 86HEX, TD2FanSelect is set to 52HEX, TD3FanSelect is set 20HEX, and other 3
left unset.
We can spilt the six registers bit by bit as above figure, and give it a rotation, this help us to
understand the relationship from the point of fan easier. For Fan1 and Fan4 row, all temperature is de-
asserted, that means Fan1/Fan4 does not have any relationship with temperature, thus they are in
manual mode under this setting. For Fan2, it is clear that it has relation with temperature 1 and 2, so it
will activate SmartFan control with temperature 1/2 as it input.
- 67 -
Publication Release Date: Dec. 11, 2006
Revision 1.0