3VSEN High Limit Bank 0 Address 6EHEX
3VSEN Low Limit Bank 0 Address 6FHEX
12VSEN High Limit Bank 0 Address 70HEX
12VSEN Low Limit Bank 0 Address 71HEX
5VDD High Limit Bank 0 Address 72HEX
5VDD Low Limit Bank 0 Address 73HEX
5VSB High Limit Bank 0 Address 74HEX
5VSB Low Limit Bank 0 Address 75HEX
VBAT High Limit Bank 0 Address 76HEX
VBAT Low Limit Bank 0 Address 77HEX
Type :
Read / Write
Reset :
VSB5V(Pin 7) Rising,
Init Reset(CR40.Bit7) is set.
Voltage High Limit
BIT
7
6
5
4
3
2
Name
Voltage High Limit
Reset
FFHEX
VOLTAGE LOW LIMIT
BIT
7
6
5
4
3
2
Name
Voltage Low Limit
Reset
00HEX
BIT
Name
Reset
7
6
Reserve
00
VIN HIGH LIMIT LOW BIT
5
4
VTTHLL
3
2
VCOREBHLL
11
11
VIN LOW LIMIT LOW BIT
BIT
7
6
5
4
3
2
Name
Reserve
VTTLLL
VCOREBLLL
Reset
00
00
00
The code calculation of high/low limit should follow the formula
  VCoreA, VCoreB, Vtt Limit Setup
CR60~66
=
[Desired Voltage]/0.008;
CR68/69
=
([Desired Voltage]/0.002) – CR60~67 * 4;
1
0
1
0
1
0
VcoreAHLL
11
1
0
VcoreALLL
00