W83793G Datasheet, PDF (77/131 Pages) Winbond – Winbond H/W Monitor
W83793G
FANSTOPTIME
BIT
7
6
5
4
3
2
1
0
Name
Reset
FanStopTime
64HEX
BIT
DESCRIPTION
FanStopTime(Fan Stop time from Nonstop level to turn off).
7-0 Unit in 0.1sec. Ranged from 0.1sec to 25.5sec.
If set to 0, Fan will never stop.
8.11.2.16 Target Temperature of Temperature Inputs Register(TempTarget)
In Thermal Cruise mode, a target temperature is needed to be defined for each temperature
source. W83793G will try to tune fan speed to keep the temperature of target device around the target
temperature. Default target temperature for diode sensors is 40℃, and 32℃ for thermistor sensors.
Location :
TD1Target - Bank 2 Address 10HEX
TD2Target - Bank 2 Address 11HEX
TD3Target - Bank 2 Address 12HEX
TD4Target - Bank 2 Address 13HEX
TR1Target - Bank 2 Address 14HEX
TR2Target - Bank 2 Address 15HEX
Type : Read / Write
Reset :
VSB5V(Pin 7) Rising,
Init Reset(CR40.Bit7) is set,
VDD5V(Pin 25) Rising @ RST_VDD_MD(CR40.Bit4) set,
SYSRSTIN_N(Pin 15) Falling @ SYSRST_MD(CR40.Bit5) set.
TD1TARGET ~ TD4TARGET
BIT
7
6
5
4
3
2
1
0
Name Reserved
TempTarget
Reset
0
28HEX
- 73 -