W83793G
ERROR
CODE
DESCRIPTION
W83793G HOST OPERATION
8000HEX
8001HEX
General Sensor Error
Sensing Device Missing
No further processing.
8002HEX
Operational, but temperature
is lower than sensor operation
range.
Force writing back temperature with 0℃ in temperature
readouts.(Bank 0 Index 1CHEX ~ 1FHEX)
8003HEX
Operational, but temperature
is higher than sensor
operation range.
Force writing back temperature with 127℃ in
temperature readouts.(Bank 0 Index 1CHEX ~ 1FHEX)
8004HEX
Reserved.
No further operation.
81FFHEX
Besides error conditions or bad FCS, normal temperature will be wrote back to Temperature
Readouts with the sum of AgtRelTemp and Tcontrol.
8.13 ASF Control Registers
ASF or Alert Standard Format provides remote system abilities to monitor, discover and manage the
local platform. All ASF control registers are allocated in Bank 1*.
*About the Bank Selection, please reference Bank Select register located at address 00Hex.
8.13.1 ASF Register Map
8.13.1.1 SMBus ARP UDID Control Registers
- 89 -
Publication Release Date: Dec. 11, 2006
Revision 1.0