English
Language : 

W83793G Datasheet, PDF (53/131 Pages) Winbond – Winbond H/W Monitor
W83793G
Continued.
MNEMONIC
REGISTER NAME
TYPE
TR1 WT/WTH. TR1 Warning Temperature / Warning Temperature Hysteresis R/W
TR2 CT/CTH. TR2 Critical Temperature / Critical Temperature Hysteresis
R/W
TR2 WT/WTH. TR2 Warning Temperature / Warning Temperature Hysteresis R/W
8.10.2 Temperature Channel Register Details
8.10.2.1 Temperature Channel Monitored Registers
Location :
TD1 Readout - Bank 0 Address 1CHEX
TD2 Readout - Bank 0 Address 1DHEX
TD3 Readout - Bank 0 Address 1EHEX
TD4 Readout - Bank 0 Address 1FHEX
Low bit Readout
- Bank 0 Address 22HEX
TR1 Readout
- Bank 0 Address 20HEX
TR2 Readout
- Bank 0 Address 21HEX
Type :
Read Only
TEMP READOUT
BIT
7
6
5
4
3
2
1
0
Name
Temperature
TD LOW BIT READOUT
BIT
7
6
5
4
3
2
1
0
Name
TD4L
TD3L
TD2L
TD1L
The format of Temperature channel readout is 2’complement. TD channel express temperature using
10-bit data including 1-bit sign bit, 7-bit integer, and 2 bits decimal. TR channel express temperature
using 8-bit data including 1-bit sign bit, and 7-bit integer.
For TD channel temperature = TDx + TDxL* 0.25
TR channel temperature = TRx
- 49 -
Publication Release Date: Dec. 11, 2006
Revision 1.0