W83793G Datasheet, PDF (78/131 Pages) Winbond – Winbond H/W Monitor
W83793G
BIT
7 Reserved.
DESCRIPTION
TempTarget. (Diode Temperature sensor target temperature).
6-0
Unit in ℃
TR1TARGET ~ TR2TARGET
BIT
7
6
5
4
3
2
1
0
Name Reserved
TempTarget
Reset
0
20HEX
BIT
7 Reserved.
DESCRIPTION
TempTarget. (Thermistor Temperature sensor target temperature).
6-0
Unit in ℃
See also : TolTemp, FanCtrlMode, Thermal Cruise mode.
8.11.2.17 Smart Fan II Fan Transition Temperature Level Registers (TempLevel)
SmartFan II, an algorithm providing a table mapping mechanism to translate temperature information
into output Fan duties. The mapping table need user to provide 2 domains for the translation, those
are at certain temperature mapping to certain duty. TempLevel(Temperature) and
TempFanLevel(Duty Cycle) are used to define the table. There totally are six tables reside in
W83793G, one table per temperature channel; 7 entries per table. Therefore here TempLevel will
have 42 registers, and another 42 registers for TempFanLevel in this and next section.
Location :
TD1Level01 - Bank 2 Address 30HEX
TD1Level12 - Bank 2 Address 31HEX
TD1Level23 - Bank 2 Address 32HEX
TD1Level34 - Bank 2 Address 33HEX
TD1Level45 - Bank 2 Address 34HEX
TD1Level56 - Bank 2 Address 35HEX
TD1Level67 - Bank 2 Address 36HEX
TD2Level01 - Bank 2 Address 40HEX
TD2Level12 - Bank 2 Address 41HEX
TD2Level23 - Bank 2 Address 42HEX
TD2Level34 - Bank 2 Address 43HEX
TD2Level45 - Bank 2 Address 44HEX