W83793G Datasheet, PDF (45/131 Pages) Winbond – Winbond H/W Monitor
W83793G
BIT
Name
Reset
VDD5V(Pin 25) Rising @ RST_VDD_MD(CR40.Bit4) set,
SYSRSTIN_N(Pin 15) Falling @ SYSRST_MD(CR40.Bit5) set.
7
6
Reserve
0
0
TD1_CONFIG
5
4
3
FaultQ1
00
0
2
1
Reserve
0
0
0
STOP1
0
BIT
DESCRIPTION
7-6 Reserved.
FaultQ1.
5-4
Number of faults to detect before setting OVT# output to avoid false tripping due to noise.
3-1 Reserved.
STOP1.
0
If temperature sensor TD1 is set as internal temperature sensor (CR5D), set to 1 the
temperature sensor will stop monitor.
8.8.2.2 TD2 Configuration (LM75B) Register (TD2_Config)
Location :
Type :
Bank 0 Address 5BHEX
Read / Write
Reset :
VSB5V(Pin 7) Rising,
Init Reset(CR40.Bit7) is set,
VDD5V(Pin 25) Rising @ RST_VDD_MD(CR40.Bit4) set,
SYSRSTIN_N(Pin 15) Falling @ SYSRST_MD(CR40.Bit5) set.
BIT
Name
Reset
7
6
Reserve
0
0
TD2_CONFIG
5
4
3
FaultQ2
00
0
2
1
Reserve
0
0
0
STOP2
0
BIT
DESCRIPTION
7-6 Reserved.
FaultQ2.
5-4
Number of faults to detect before setting OVT# output to avoid false tripping due to noise.
3-1 Reserved.
STOP2.
0
If temperature sensor TD2 is set as internal temperature sensor (CR5D), set to 1 the
temperature sensor will stop monitor.
- 41 -
Publication Release Date: Dec. 11, 2006
Revision 1.0