English
Language : 

W83793G Datasheet, PDF (34/131 Pages) Winbond – Winbond H/W Monitor
W83793G
8.5.2.3 Real Time status Register (REAL_STS)
Real-time status registers show the related channel exceeding limit or not at the polling moment.
Return 1 represents related channel has exceeded the limit defined in limit registers.
Location :
REAL_STS1 - Bank 0 Address 4BHEX
REAL_STS2 - Bank 0 Address 4CHEX
REAL_STS3 - Bank 0 Address 4DHEX
REAL_STS4 - Bank 0 Address 4EHEX
REAL_STS5 - Bank 0 Address 4FHEX
Type : Read Only
Reset : VSB5V(Pin 7) Rising,
Init Reset(CR40.Bit7) is set,
VDD5V(Pin 25) Rising @ RST_VDD_MD(CR40.Bit4) set,
SYSRSTIN_N(Pin 15) Falling @ SYSRST_MD(CR40.Bit5) set.
REAL_STS1
BIT
7
6
5
4
3
2
1
0
Name 12VSEN 3VSEN VSEN2 VSEN1 Reserve VTT VCOREB VCOREA
Reset
0
0
0
0
0
0
0
0
REAL_STS2
BIT
7
6
5
4
3
2
1
0
Name
TD4
TD3
TD2
TD1 VIDCHG VBAT
5VSB
5VDD
Reset
0
0
0
0
0
0
0
0
REAL_STS3
BIT
7
6
5
4
3
2
1
0
Name FANIN6 FANIN5 FANIN4 FANIN3 FANIN2 FANIN1 TR2
TR1
Reset
0
0
0
0
0
0
0
0
BIT
Name
Reset
7
Reserve
0
6
Chassis
0
REAL_STS4
5
4
3
FANIN12 FANIN11 FANIN10
0
0
0
2
FANIN9
0
1
FANIN8
0
0
FANIN7
0
- 30 -