English
Language : 

W83793G Datasheet, PDF (114/131 Pages) Winbond – Winbond H/W Monitor
W83793G
BIT
DESCRIPTION
7-1
Winbond Test Mode. Test modes for production. Winbond strongly suggest customer do
not use these registers in case of causing system malfunction.
PWR1T (Power on One Time).
0
0: always issue power on cycles (PWRBTN_N assert 0.1sec every 1sec) until VDD power
on.
1: Only issue 1 time power on cycle.
8.13.2.13 Power On Command Register (PwrOnCmd)
ASF Remote Control Command supports Remote Power On features, here defines the Power on
commands accepted by W83793G.
Location: PwrOnCmd - Bank 1 Address 80HEX
Type: Read Write
Reset: VSB5V (Pin 7) Rising.
BIT
7
6
Name
Reset
PWRONCMD
5
4
3
2
1
0
Remote Power On Command
11HEX
BIT
7-0 Remote Power On Command.
DESCRIPTION
8.13.2.14 Power Down Command Register (PwrOffCmd)
ASF Remote Control Command supports Remote Power Down features, here defines the Power off
commands accepted by W83793G.
Location: PwrOffCmd - Bank 1 Address 81HEX
Type: Read Write
Reset: VSB5V (Pin 7) Rising.
BIT
7
6
Name
Reset
PWROFFCMD
5
4
3
2
1
0
Remote Power Off Command
12HEX
- 110 -