English
Language : 

W83793G Datasheet, PDF (75/131 Pages) Winbond – Winbond H/W Monitor
W83793G
8.11.2.13 Fan Output Nonstop Duty Cycle Register(FanNonStop)
Due to bring a fan from stop to work might take some time. The design of FanNonStop is hope to have
a minimum duty cycle to keep the fan rotating when system does not require fan help getting ride of
heat but still want to keep the fast response time to speed up fan. (Reference to Graph)
Location :
Fan1NonStop - Bank 2 Address 18HEX
Fan2NonStop - Bank 2 Address 19HEX
Fan3NonStop - Bank 2 Address 1AHEX
Fan4NonStop - Bank 2 Address 1BHEX
Fan5NonStop - Bank 2 Address 1CHEX
Fan6NonStop - Bank 2 Address 1DHEX
Fan7NonStop - Bank 2 Address 1EHEX
Fan8NonStop - Bank 2 Address 1FHEX
Type : Read / Write
Reset :
VSB5V(Pin 7) Rising,
Init Reset(CR40.Bit7) is set,
VDD5V(Pin 25) Rising @ RST_VDD_MD(CR40.Bit4) set,
SYSRSTIN_N(Pin 15) Falling @ SYSRST_MD(CR40.Bit5) set.
FANNONSTOP
BIT
7
6
5
4
3
2
1
0
Name
Reserved
FanNonStop
Reset
0
4HEX
BIT
DESCRIPTION
7-6 Reserved.
5-0 FanNonStop(Fan Output NonStop Duty Cycle).
8.11.2.14 Fan Output Start Duty Cycle Register(FanStart)
From still to rotate, Fan usually needs a higher duty cycle to generate enough torque to conquer the
restriction force. Thus W83793G include a FanStart to bring the Fan live with the duty specified.
(Reference to Graph)
Location :
Fan1Start - Bank 2 Address 20HEX
Fan2Start - Bank 2 Address 21HEX
Fan3Start - Bank 2 Address 22HEX
Fan4Start - Bank 2 Address 23HEX
- 71 -
Publication Release Date: Dec. 11, 2006
Revision 1.0