English
Language : 

W83793G Datasheet, PDF (54/131 Pages) Winbond – Winbond H/W Monitor
8.10.2.2 Temperature Channel Limitation Registers
Location:
TD1 Critical
- Bank 0 Address 78HEX
TD1 Critical Hystersis - Bank 0 Address 79HEX
TD1 Warning
- Bank 0 Address 7AHEX
TD1 Warning Hystersis - Bank 0 Address 7BHEX
TD2 Critical
- Bank 0 Address 7CHEX
TD2 Critical Hystersis - Bank 0 Address 7DHEX
TD2 Warning
- Bank 0 Address 7EHEX
TD2 Warning Hystersis - Bank 0 Address 7FHEX
TD3 Critical
- Bank 0 Address 80HEX
TD3 Critical Hystersis - Bank 0 Address 81HEX
TD3 Warning
- Bank 0 Address 82HEX
TD3 Warning Hystersis - Bank 0 Address 83HEX
TD4 Critical
- Bank 0 Address 84HEX
TD4 Critical Hystersis - Bank 0 Address 85HEX
TD4 Warning
- Bank 0 Address 86HEX
TD4 Warning Hystersis - Bank 0 Address 87HEX
TR1 Critical
- Bank 0 Address 88HEX
TR1 Critical Hystersis - Bank 0 Address 89HEX
TR1 Warning
- Bank 0 Address 8AHEX
TR1 Warning Hystersis-Bank 0 Address 8BHEX
TR2 Critical
- Bank 0 Address 8CHEX
TR2 Critical Hystersis - Bank 0 Address 8DHEX
TR2 Warning
- Bank 0 Address 8EHEX
TR2 Warning Hystersis- Bank 0 Address 8FHEX
Type:
Read / Write
Reset:
VSB5V (Pin 7) Rising.
BIT
7
Name
Reset
SENSOR CRITICAL TEMPERATURE
6
5
4
3
2
Temp Critical Temperature
64HEX (100 C)
W83793G
1
0
- 50 -