W83791D/G
2. FEATURES
2.1 Monitoring Items
⢠10 voltage inputs
--- Typical for VCORE, +3.3V, +12V, -12V, +5V, -5V, +5VSB, VBAT, and two reserved
⢠5 fan speed monitoring inputs
⢠3 temperature inputs from remote thermistors, 2N3904 NPN-type transistors or PentiumTM II
(Deschutes) thermal diode output
⢠Case open detection input
⢠WATCHDOG comparison of all monitored values
⢠Programmable hysteresis and setting points (alarm thresholds) for all monitored items
2.2 Address Resolution Protocol (ARP) and Alert-Standard Forum (ASF)
⢠Support System Management Bus (SMBus) version 2.0 specification
⢠Comply with hardware sensor slave ARP (Address Resolution Protocol)
⢠Response sensor type ARP command
⢠Response ASF command --- Get Event Data , Get Event Status
⢠Comply with ASF sensors (Monitoring fan speed, voltage, temperature, and case open)
2.3 Speech Items
⢠Programmable speech synthesizer with new high fidelity synthesis algorithm
⢠Build in 8-bit current D/A converter
⢠1 CPU present or absent trigger input
⢠5 External trigger inputs
⢠128 Internal programmable trigger inputs
⢠17 H/W Monitor event trigger inputs
⢠Programmable 0-255 seconds timeout trigger inputs for firmware or software
⢠Instruction cycle is <= 400 uS typically
⢠Section control provided in each voice section
⢠External resistor for ring oscillator
2.4 Actions Enabling
⢠Beep tone warning separated speech output
⢠5 PWM (pulse width modulation) outputs for fan speed control (1~3 support Smart Fan control) and
5 Fan speed inputs for monitoring --- Total up to 5 sets of fan speed monitoring and controlling
⢠Issue SMI#, OVT#, IRQ signals to activate system protection
⢠Warning signal pop-up in application software
Publication Release Date: April 14, 2006