W83791G Datasheet, PDF (50/99 Pages) Winbond – Winbond H/W Monitoring IC
W83791D/G
7.36 SMI#/OVT# Property Select ⎯ Index 4Ch (Bank 0)
Power on default: 01h
BIT
NAME
7-6 TEMP_SMI_MD
[1:0]
5-4 OVT_MD[1:0]
3 EN_OVT3
ATTRIBUTE
R/W
R/W
R/W
DESCRIPTION
Temperature SMI# Mode Select.
<00> - Comparator Interrupt Mode:
Temperature 1/2/3 exceeds TO (Over-temperature) limit
causes and interrupt and this interrupt will be reset by
reading all the Interrupt Staus.
<01> - Two Time Interrupt Mode:(Default)
This bit use in temperature sensor 1/2/3 interrupt mode
with hysteresis type. Temperature exceeding TO, causes
an interrupt and then temperature going below THYST will
also cause an interrupt if the previous interrupt has been
reset by reading all the interrupt Status Register. Once an
interrupt event has occurred by exceeding TO, then reset, if
the temperature remains above the THYST.
<10> - One Time Interrupt Mode:
This bit use in temperature sensor 1/2/3 interrupt mode
with hysteresis type. Temperature exceeding TO (Over-
temperature, defined in Bank 1/2) causes an interrupt and
then temperature going below THYST (Hysteresis
temperature, defined in Bank 1/2) will not cause an
interrupt. Once an interrupt event has occurred by
exceeding TO, then going below THYST, and interrupt will not
occur again until the temperature exceeding TO.
OVT# Mode Select. There are three OVT# signal output
type.
<00> - Comparator Mode: (Default)
Temperature exceeding TO causes the OVT# output
activated until the temperature is less than THYST.
<01> - Interrupt Mode:
Setting temperature exceeding TO causes the OVT# output
activated indefinitely until reset reading temperature sensor
1/2/3 registers. Temperature exceeding TO, then OVT#
reset, and then temperature going below THYST will also
cause the OVT# activated indefinitely until reset by reading
temperature sensor 1/2/3. Once the OVT# will not be
activated by exceeding TO, then reset, if the temperature
remains above THYST, the OVT# will not be activated again.
<10> - ACPI Mode:
If set to 1 then enable ACPI OVT# output. Which always
send an OVT# signal when the temperature over the ACPI
temperature increment value defined at Index 5Eh.
Enable temperature sensor 3 over-temperature (OVT)
output if set to 1. Default is 0, disable OVT2 output through
pin OVT#. The pin OVT# is wire OR with OVT1 and OVT2.
- 44 -
Publication Release Date: April 14, 2006
Revision 1.1