8.3.4 Entity Instance Register
Maximum number of instance is 15
INDEX
BIT
ENTITY
ENTITY INSTANCE (DEFAULT VALUE)
70h <7:4>
VIN0(Vcore) 1 (Processor 1_CPU1).
<3:0>
VIN1(VINR0) 1 (System board 1).
71h <7:4>
VIN2 (+3.3VIN) 1 (System board 1).
<3:0>
VIN3 (+5VIN) 1 (System board 1).
72h <7:4>
VIN4 (+12VIN) 1 (System board 1).
<3:0>
VIN5 (-12VIN) 1 (System board 1).
73h <7:4>
VIN6 (-5VIN) 1 (System board 1).
<3:0>
VIN7(VSB)
1 (System board 1).
74 h <7:4>
VIN8(VBAT) 1 (System board 1).
<3:0>
VIN9(VINR1) 2 (Processor 2_CPU2).
75h <7:4>
FAN1
1 (System board 1).
<3:0>
FAN2
1 (Processor 1_CPU1).
76h <7:4>
FAN3
2 (Processor 2_CPU2)
<3:0>
TEMP1
1 (System board 1)
77h <7:4>
TEMP2
1 (Processor 1)
<3:0>
TEMP3
2 (Processor 2)
78h <7:4>
Reserved
0
<3:0>
Chassis
1 (System Chassis)
The Entity for a given event varies according to what entity the environmental sensor is monitoring.
For example, a typical managed system board can have temperature monitoring associated with the
system board and with the main processor. Thus, the Entity IDs and Entity Instance values for these
would be Entity ID=7, Entity Instance=1 for ‘main system board’ and Entity ID=3, Entity Instance=1 for
‘processor 1’, respectively.
8.4 BJT RT-Table - 50h-57h (Bank 7) ⎯ TEST mode only
Bank 7 registers 50h-57h are BJT table for Winbond test. User doesn’t use these registers.
- 82 -
Publication Release Date: April 14, 2006
Revision 1.1