English
Language : 

W83791G Datasheet, PDF (74/99 Pages) Winbond – Winbond H/W Monitoring IC
W83791D/G
7.96 Temperature Sensor 2 Configuration Register ⎯ Index C2h (Bank 0)
Power on default: 00h; Reset by MR
BIT
7-5
4-3
NAME
Reserved
FAULT
2:1
Reserved
0
STOP2
ATTRIBUTE
R/W
R/W
DESCRIPTION
Reserved
Number of faults to detect before setting OVT# output to
avoid false tripping due to noise.
Reserved
When set to 1 the sensor will stop monitor.
7.97 Temperature Sensor 2 Hysteresis (High Byte) Register ⎯ Index C3h (Bank 0)
Power on default: 4Bh; Reset by MR
BIT
NAME
ATTRIBUTE
DESCRIPTION
7-0 THYST2<8:1> R/W
Temperature hysteresis bit 8-1, which is High Byte. The
temperature default 75 degree C.
7.98 Temperature Sensor 2 Hysteresis (Low Byte) Register ⎯ Index C4h (Bank 0)
Power on default: 00h; Reset by MR
BIT
NAME
ATTRIBUTE
DESCRIPTION
7
THYST2<0> R/W
Temperature hysteresis bit 0, which is low Byte.
6-0
Reserved
Read Only Read 0
7.99 Temperature Sensor 2 Over-temperature (High Byte) Register ⎯ Index C5h
(Bank 0)
Power on default: 50h; Reset by MR
BIT
NAME
ATTRIBUTE
DESCRIPTION
7-0
TOVF2<8:1> R/W
Over-temperature bit 8-1, which is High Byte. The
temperature default 80 degree C.
7.100 Temperature Sensor 2 Over-temperature (Low Byte) Register ⎯ Index C6h
(Bank 0)
Power on default: 00h; Reset by MR.
BIT
NAME
ATTRIBUTE
DESCRIPTION
7
TOVF2<0> R/W
Over-temperature bit 0, which is low Byte.
6-0
Reserved
Read Only Read 0
- 68 -
Publication Release Date: April 14, 2006
Revision 1.1