W83791G Datasheet, PDF (72/99 Pages) Winbond – Winbond H/W Monitoring IC
W83791D/G
Real Time Hardware Status Register II ⎯ Index AAh (Bank 0), continued.
BIT
NAME
ATTRIBUTE
DESCRIPTION
3
FAN3
Read Only Set 1, the fan speed counter is over the limit value. Set 0, the
fan speed counter is during the limit range.
2
-5VIN
Read Only Set 1, the voltage of -5V is over the limit value. Set 0, the
voltage of -5V is during the limit range.
1
-12VIN
Read Only Set 1, the voltage of -12V is over the limit value. Set 0, the
voltage of -12V is during the limit range.
0
+12VIN
Read Only Set 1, the voltage of +12V is over the limit value. Set 0, the
voltage of +12V is in the limit range.
7.91 Real Time Hardware Status Register III ⎯ Index ABh (Bank 0)
Power on default: 00h; Reset by MR.
BIT
NAME
ATTRIBUTE
DESCRIPTION
7
Reserved
Reserved.
6
FAN5
Read Only Set 1, the fan speed counter is over the limit value. Set 0, the
fan speed counter is during the limit range.
5
FAN4
Read Only Set 1, the fan speed counter is over the limit value. Set 0, the
fan speed counter is during the limit range.
4
VBAT
Read Only Set 1, the voltage of VBAT is over the limit value. Set 0, the
voltage of VBAT is during the limit range.
3
VSB
Read Only Set 1, the voltage of VSB is over the limit value. Set 0, the
voltage of VSB is in the limit range.
2
TART3
Read Only
Set 1, when target temperature 3 with Fan 3 full speed can not
be in the range after 3 minutes. Set 0, the temperature or
speed is in the specific range.
1
TART2
Read Only
Set 1, when target temperature 2 with Fan 2 full speed can not
be in the range after 3 minutes. Set 0, the temperature or
speed is in the specific range.
0
TART1
Read Only
Set 1, when target temperature 1 with Fan 3 full speed can not
be in the range after 3 minutes. Set 0, the temperature or
speed is in the specific range.
- 66 -
Publication Release Date: April 14, 2006
Revision 1.1