English
Language : 

W83791G Datasheet, PDF (75/99 Pages) Winbond – Winbond H/W Monitoring IC
W83791D/G
7.101 Temperature Sensor 3 Temperature (High Byte) Register ⎯ Index C8h
(Bank 0)
BIT
7-0
NAME
ATTRIBUTE
DESCRIPTION
TEMP3<8:1> Read Only Temperature <8:1> of VTIN3, which is high byte.
7.102 Temperature Sensor 3 Temperature (Low Byte) Register ⎯ Index C9h
(Bank 0)
BIT
7
6-0
NAME
TEMP3<0>
Reserved
ATTRIBUTE
Read Only
Read Only
DESCRIPTION
Temperature <0> of VTIN3, which is low byte.
Read 0.
7.103 Temperature Sensor 3 Configuration Register ⎯ Index CAh (Bank 0)
Power on default: 00h; Reset by MR.
BIT
NAME
ATTRIBUTE
DESCRIPTION
7-5
Reserved
Reserved
4-3
FAULT
R/W
Number of faults to detect before setting OVT# output to
avoid false tripping due to noise.
2:1
Reserved
R/W
Reserved
0
STOP3
R/W
When set to 1 the sensor will stop monitor.
7.104 Temperature Sensor 3 Hysteresis (High Byte) Register ⎯ Index CBh (Bank
0)
Power on default: 4Bh; Reset by MR.
BIT
NAME
ATTRIBUTE
DESCRIPTION
7-0 THYST3<8:1> R/W
Temperature hysteresis bit 8-1, which is High Byte. The
temperature default 75 degree C.
7.105 Temperature Sensor 3 Hysteresis (Low Byte) Register ⎯ Index CCh (Bank
0)
Poweron default: 00h; Reset by MR.
BIT
NAME
ATTRIBUTE
DESCRIPTION
6-0
Reserved
Read Only
Read 0
7
THYST3<0> R/W
Temperature hysteresis bit 0, which is low Byte.
- 69 -
Publication Release Date: April 14, 2006
Revision 1.1