Bit 7:
Bit 6~4:
Bit 3:
Bit 2~0:
IR_MSP - IR Mode Select Pulse
When set to 1, the transmitter (IRTX) will send a 64 μs pulse to setup a special IR front-
end operational mode. When IR front-end module uses mode select pin (MD) and
transmitter IR pulse (IRTX) to switch between high speed IR (such as FIR or MIR) and
low speed IR (SIR or ASK-IR), this bit should be used.
SIR_SL2~0 - SIR (Serial IR) mode select.
These bits are used to program the operational mode of the SIR front-end module.
These values of SIR_SL2~0 will be automatically loaded to pins of IR_SL2~0,
respectively, when (1) AM_FMT=1 (Automatic Format, in Set7.Reg7.Bit7); (2) the mode
of Advanced IR is set to SIR (AD_MD2~0, in Set0.Reg4.Bit7~0).
Reserved, write 0.
AIR_SL2~0 - ASK-IR Mode Select.
These bits setup the operational mode of ASK-IR front-end module when AM_FMT=1 and
AD_MD2~0 are configured to ASK-IR mode. These values will be automatically loaded to
IR_SL2~0, respectively.
7.9.6 Set7.Reg5 - Infrared Module (Front End) Select 2 (IRM_SL2)
REG.
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
IRM_SL2
-
FIR_SL2 FIR_SL1 FIR_SL0
-
MIR_SL2 MIR_SL1 MIR_SL0
Default Value
0
0
0
0
0
0
0
0
Bit 7:
Bit 6~4:
Bit 3:
Bit 2~0:
Reserved, write 0.
FIR_SL2~0 - FIR mode select.
These bits setup the operational mode of FIR front-end module when AM_FMT=1 and
AD_MD2~0 are configured to FIR mode. These values will be automatically loaded to
IR_SL2~0, respectively.
Reserved, write 0.
MIR_SL2~0 - MIR Mode Select.
These bits setup the MIR operational mode when AM_FMT=1 and AD_MD2~0 are
configured to MIR mode. These values will be automatically loaded to IR_SL2~0,
respectively.
7.9.7 Set7.Reg6 - Infrared Module (Front End) Select 3 (IRM_SL3)
REG.
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
IRM_SL3
-
LRC_SL2 LRC_SL1 LRC_SL0
-
HRC_SL2 HRC_SL1 HRC_SL0
Default Value
0
0
0
0
0
0
0
0