English
Language : 

MSP430FR2033 Datasheet, PDF (19/89 Pages) Texas Instruments – Mixed-Signal Microcontrollers
www.ti.com
MSP430FR2033, MSP430FR2032
SLASE45B – OCTOBER 2014 – REVISED AUGUST 2015
5.12.2 Reset Timing
Table 5-2. Wake-Up Times From Low-Power Modes and Reset
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
TEST
CONDITIONS
VCC
MIN TYP
MAX UNIT
tWAKE-UP FRAM
Additional wake-up time to activate the FRAM in
AM if previously disabled by the FRAM controller or
from a LPM if immediate activation is selected for
wakeup (1)
3V
10
µs
tWAKE-UP LPM0
Wake-up time from LPM0 to active mode(1)
3V
tWAKE-UP LPM3
Wake-up time from LPM3 to active mode (2)
3V
tWAKE-UP LPM4 Wake-up time from LPM4 to active mode
3V
tWAKE-UP LPM3.5 Wake-up time from LPM3.5 to active mode (2)
3V
tWAKE-UP LPM4.5 Wake-up time from LPM4.5 to active mode (2)
SVSHE = 1
SVSHE = 0
3V
3V
200 ns +
2.5/fDCO
10
µs
10
µs
350
µs
350
µs
1
ms
tWAKE-UP-RESET
Wake-up time from RST or BOR event to active
mode (2)
3V
1
ms
tRESET
Pulse duration required at RST/NMI pin to accept a
reset
3V
2
µs
(1) The wake-up time is measured from the edge of an external wake-up signal (for example, port interrupt or wake-up event) to the first
externally observable MCLK clock edge.
(2) The wake-up time is measured from the edge of an external wake-up signal (for example, port interrupt or wake-up event) until the first
instruction of the user program is executed.
Copyright © 2014–2015, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: MSP430FR2033 MSP430FR2032
Specifications