C2510Fx / CC2511Fx
Mnemonic
Description
MOV Rn,#data
MOV direct,A
MOV direct,Rn
MOV direct1,direct2
MOV direct,@Ri
MOV direct,#data
MOV @Ri,A
MOV @Ri,direct
MOV @Ri,#data
MOV DPTR,#data16
MOVC A,@A+DPTR
MOVC A,@A+PC
MOVX A,@Ri
MOVX A,@DPTR
MOVX @Ri,A
MOVX @DPTR,A
PUSH direct
POP direct
XCH A,Rn
XCH A,direct
XCH A,@Ri
XCHD A,@Ri
Program Branching
ACALL addr11
LCALL addr16
RET
RETI
AJMP addr11
LJMP addr16
SJMP rel
JMP @A+DPTR
JZ rel
JNZ rel
JC rel
JNC
JB bit,rel
JNB bit,rel
JBC bit,direct rel
CJNE A,direct rel
CJNE A,#data rel
CJNE Rn,#data rel
CJNE @Ri,#data rel
Move immediate data to register
Move accumulator to direct byte
Move register to direct byte
Move direct byte to direct byte
Move indirect RAM to direct byte
Move immediate data to direct byte
Move accumulator to indirect RAM
Move direct byte to indirect RAM
Move immediate data to indirect RAM
Load data pointer with a 16-bit constant
Move code byte relative to DPTR to accumulator
Move code byte relative to PC to accumulator
Move external RAM (8-bit address) to A
Move external RAM (16-bit address) to A
Move A to external RAM (8-bit address)
Move A to external RAM (16-bit address)
Push direct byte onto stack
Pop direct byte from stack
Exchange register with accumulator
Exchange direct byte with accumulator
Exchange indirect RAM with accumulator
Exchange low-order nibble indirect. RAM with A
Absolute subroutine call
Long subroutine call
Return from subroutine
Return from interrupt
Absolute jump
Long jump
Short jump (relative address)
Jump indirect relative to the DPTR
Jump if accumulator is zero
Jump if accumulator is not zero
Jump if carry flag is set to 1
Jump if carry flag is 0
Jump if direct bit is set to 1
Jump if direct bit is 0
Jump if direct bit is set to 1 and clear the bit to 0
Compare direct byte to A and jump if not equal
Compare immediate to A and jump if not equal
Compare immediate to reg. and jump if not equal
Compare immediate to indirect and jump if not equal
Hex
Opcode
78-7F
F5
88-8F
85
86-87
75
F6-F7
A6-A7
76-77
90
93
83
E2-E3
E0
F2-F3
F0
C0
D0
C8-CF
C5
C6-C7
D6-D7
Bytes
2
2
2
3
2
3
1
2
2
3
1
1
1
1
1
1
2
2
1
2
1
1
Cycles
2
3
3
4
4
3
3
5
3
3
3
3
3-10
3-10
4-11
4-11
4
3
2
3
3
3
xxx11
2
6
12
3
6
22
1
4
32
1
4
xxx01
2
3
02
3
4
80
2
3
73
1
2
60
2
3
70
2
3
40
2
3
50
2
3
20
3
4
30
3
4
10
3
4
B5
3
4
B4
3
4
B8-BF 3
4
B6-B7 3
4
SWRS055D
Page 56 of 243