English
Language : 

CC2510FX Datasheet, PDF (11/244 Pages) List of Unclassifed Manufacturers – True System-on-Chip with Low Power RF Transceiver and 8051 MCU
C2510Fx / CC2511Fx
Parameter
Active mode with
radio in RX
Active mode with
radio in TX
PM0
PM1
PM2
PM3
Peripheral
Current
Consumption
Timer 1
Timer 2
Timer 3
Timer 4
ADC
Min Typ Max
20.6
22.1
22.7
20.8
26
18.5
15.5
26
4.3
220
0.5
1
0.3
1
Unit Condition
System clock running at 24 MHz.
Digital regulator on. High speed crystal oscillator and low power
RCOSC running. Radio in RX mode (sensitivity optimized
MDMCFG2.DEM_DCFILT_OFF=0)
mA 2.4 kBaud, input at sensitivity limit
mA 10 kBaud, input at sensitivity limit
mA 250 kBaud, input at sensitivity limit
mA 500 kBaud, input at sensitivity limit
System clock running at 26 MHz.
Digital regulator on. High speed crystal oscillator and low power
RCOSC running. Radio in TX mode
mA 0 dBm output power (PA_TABLE0=0xFE). See Table 7 for typical
variation over operating conditions
mA -6 dBm output power (PA_TABLE0=0x7F)
mA -12 dBm output power (PA_TABLE0=0x95)
mA System clock running at 24 MHz.
Digital regulator on. High speed crystal oscillator and low power
RCOSC running. Radio in TX mode w/0 dBm output power
(PA_TABLE0=0xFE)
mA Same as active mode, but the CPU is not running (see 13.1.2.2 for
details). System clock running at 26 MHz
µA
Digital regulator on. HS RCOSC and high speed crystal oscillator off.
32.768 kHz XOSC or low power RCOSC running (see 13.1.2.3 for
details)
µA
Digital regulator off. HS RCOSC and high speed crystal oscillator off.
Low power RCOSC running (see 13.1.2.4 for details)
µA
Digital regulator off. No crystal oscillators or RC oscillators are
running (see 13.1.2.5 for details)
Add to the figures above if the peripheral unit is activated
2.7
µA/MHz When running
1.3
µA/MHz When running
1.6
µA/MHz When running
2
µA/MHz When running
1.2
mA During conversion
Table 6: Current Consumption
SWRS055D
Page 11 of 243