English
Language : 

CC2510FX Datasheet, PDF (112/244 Pages) List of Unclassifed Manufacturers – True System-on-Chip with Low Power RF Transceiver and 8051 MCU
C2510Fx / CC2511Fx
0xFFFF
0x0000
OVFIF = 1
OVFIF = 1
Figure 28: Free-running Mode
13.6.2.2 Modulo Mode
In modulo mode the counter starts from
0x0000 and increments at each active clock
edge. When the counter value matches the
terminal count value T1CC0 (overflow), held in
the registers T1CC0H:T1CC0L, the counter is
loaded with 0x0000 and continues
incrementing its value as shown in Figure 29.
When T1CC0 is reached, the T1CTL.OVFIF
flag is set. The IRCON.T1IF flag is only
asserted if the corresponding interrupt mask
bit TIMIF.OVFIM is set. An interrupt request
is generated when both TIMIF.OVFIM and
IEN1.T1EN are set to 1. The modulo mode
can be used for applications where a period
other than 0xFFFF is required.
T1CC0
0x0000
OVFIF = 1
OVFIF = 1
Figure 29: Modulo Mode
13.6.2.3 Up/Down Mode
In up/down mode the counter starts from
0x0000 and increments at each active clock
edge. When the counter value matches the
terminal count value T1CC0, held in the
registers T1CC0H:T1CC0L, the counter counts
down until 0x0000 is reached and it starts
counting up again as shown in Figure 30.
When 0x0000 is reached, the T1CTL.OVFIF
flag is set. The IRCON.T1IF flag is only
asserted if the corresponding interrupt mask
bit TIMIF.OVFIM is set. An interrupt request
is generated when both TIMIF.OVFIM and
IEN1.T1EN are set to 1. The up/down mode
can be used when symmetrical output pulses
are required with a period other than 0xFFFF,
and therefore allows implementation of centre-
aligned PWM output applications.
T1CC0
0x0000
OVFIF = 1
Figure 30: Up/Down Mode
OVFIF = 1
13.6.3 Channel Mode Control
The channel mode is set with each channel’s
control and status register T1CCTLn. The
settings include input capture and output
compare modes.
SWRS055D