English
Language : 

SAB80515 Datasheet, PDF (54/270 Pages) Siemens Semiconductor Group – 8-Bit Single-Chip Microcontroller Family
On-Chip Peripheral Components
Table 7-5
Baud Rates of Serial Interface 0
Baud Rate Derived
from
Timer 1 in mode 1
Interface
Mode
1, 3
Timer 1 in mode 2
1, 3
Oscillator
2
Baud rate generator 1, 3
Baud Rate
2SMOD 1
x x (timer 1 overflow rate)
2 16
2SMOD 1
xx
fOSC
2 16 12 x (256 – (TH1))
2SMOD
x
1
x fOSC
2 16 2
2SMOD
x
1
x
fOSC
2 16 1250
7.2.4 Detailed Description of the Operating Modes
The following sections give a more detailed description of the several operating modes of the serial
interface.
7.2.4.1 Mode 0, Synchronous Mode
Serial data enters and exits through RxD. TxD outputs the shift clock. 8 bits are transmitted/
received: 8 data bits (LSB first). The baud rate is fixed at 1/12 of the oscillator frequency.
Figures 7-16 a) and b) show a simplified functional diagram of the serial port in mode 0, and
associated timing.
Transmission is initiated by any instruction that uses SBUF as a destination register. The "write-to-
SBUF" signal at S6P2 also loads a 1 into the 9th bit position of the transmit shift register and tells
the TX control block to commence a transmission. The internal timing is such that one full machine
cycle will elapse between "write-to-SBUF" and activation of SEND.
Semiconductor Group
54