English
Language : 

MC68HC908JL3E Datasheet, PDF (135/226 Pages) Motorola, Inc – Microcontrollers
Timer Interface Module (TIM)
I/O Registers
TSTOP — TIM Stop Bit
This read/write bit stops the TIM counter. Counting resumes when
TSTOP is cleared. Reset sets the TSTOP bit, stopping the TIM
counter until software clears the TSTOP bit.
1 = TIM counter stopped
0 = TIM counter active
NOTE: Do not set the TSTOP bit before entering wait mode if the TIM is required
to exit wait mode.
TRST — TIM Reset Bit
Setting this write-only bit resets the TIM counter and the TIM
prescaler. Setting TRST has no effect on any other registers.
Counting resumes from $0000. TRST is cleared automatically after
the TIM counter is reset and always reads as logic zero. Reset clears
the TRST bit.
1 = Prescaler and TIM counter cleared
0 = No effect
NOTE: Setting the TSTOP and TRST bits simultaneously stops the TIM counter
at a value of $0000.
PS[2:0] — Prescaler Select Bits
These read/write bits select one of the seven prescaler outputs as the
input to the TIM counter as Table 10-2 shows. Reset clears the
PS[2:0] bits.
Table 10-2. Prescaler Selection
PS2 PS1 PS0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
TIM Clock Source
Internal Bus Clock ÷ 1
Internal Bus Clock ÷ 2
Internal Bus Clock ÷ 4
Internal Bus Clock ÷ 8
Internal Bus Clock ÷ 16
Internal Bus Clock ÷ 32
Internal Bus Clock ÷ 64
Not available
MC68H(R)C908JL3E/JK3E/JK1E — Rev. 2.0
MOTOROLA
Timer Interface Module (TIM)
Technical Data
135