English
Language : 

MAX11410 Datasheet, PDF (44/95 Pages) Maxim Integrated Products – 24-Bit Multi-Channel Low-Power
MAX11410
24-Bit Multi-Channel Low-Power
1.9ksps Delta-Sigma ADC with PGA
GP_CONV (0x06)
The GP_CONV register selects the type of conversion to be performed when initiated by a GPIO (when the GPIO is
configured as a Conversion Start input), and selects the register to which the conversion result will be written. Writing to
this register does not execute a conversion. When a GPIO initiates a conversion, the conversion results will be written to
the data register selected by the GPIO Conversion Destination field (GP_DEST). The GPIO Conversion Type field selects
the type of conversion that will be initiated by a GPIO.
BIT
7
6
5
4
3
2
1
0
Field
—
GP_DEST[2:0]
—
—
GP_CONV_TYPE[1:0]
Reset
—
—
—
Access Type
—
Write, Read
—
—
Write, Read
BITFIELD
BITS
GP_DEST
6:4
GP_CONV_
TYPE
1:0
DESCRIPTION
DECODE
000: Store result in DATA0
001: Store result in DATA1
010: Store result in DATA2
011: Store result in DATA3
100: Store result in DATA4
101: Store result in DATA5
110: Store result in DATA6
111: Store result in DATA7
00: Single conversion
01: Continuous conversions
10, 11: 1:4 Duty cycled conversions (modulator
low-power mode)
GP_SEQ_ADDR (0x07)
The GP_SEQ_ADDR register selects the target sequencer address when a sequence is initiated by a GPIO (when the
GPIO is configured as a Sequencer Start input). Writing to this register does not initiate a sequence. Valid values are
0x3A - 0x6F. Writes of invalid addresses will be ignored.
BIT
7
6
5
4
3
2
1
0
Field
—
GP_SEQ_ADDR[6:0]
Reset
—
0x3A
Access Type
—
Write, Read
BITFIELD
GP_SEQ_ADDR
BITS
6:0
DESCRIPTION
Write the address of the Sequencer (Microcode) register at which a sequence
should be initiated by a Sequencer Start GPIO event.
www.maximintegrated.com