English
Language : 

D20419-80 Datasheet, PDF (98/386 Pages) ITT Industries – Military/Aerospace
Rack and Palnel Connectors
DPGM/DPJM/DPJMB
Contact Arrangements
DPGM
4
3
2
1
8
7
6
5
4
3
2
5
1
7
6
12
8
11
10
9
15
10
7
9
8
12
13
11
3
1
5
2
4
14
6
1
6
2
5
4
3
8
10
9
7
13
16
15
14
11
12
No. of Contacts & Wire Size
Test Voltage AC (RMS)
C8*
8 coax (1-8)
1000
12*
12 #16 (1-12)
See note
15*
15 #16 (1-15)
See note
16*
5 #20 (3,6,10,11 & 16)
1500
9 #20 (1,4,5,7-9, 13-15)
1700
(2 #20 (2&12)
1500
4
3
2
1
12
11
10
9
8
7
6
5
20
19
18
17
16
15
14
13
7
6
5
4
3
2
1
14
13
12
11
10
21
20
19
18
17
9
8
16
15
8
7
6
5
4
3
2
1
16
15
14
13
12
11
10
9
24
23
22
21
20
19
18
17
32
31
30
29
28
27
26
25
No. of Contacts & Wire Size
Test Voltage AC (RMS)
20C4*
16 #20 (5-20)
1500
4 COAX (1-4)
1000
21*
21 #20 (1-21)
1500
32*
32 #20 (1-32)
1500
*All DPGM arrangements have a 1500 VAC test voltage except for arrangements 12 and 15, which is 3200 VAC for contact 1,5,8 and 12. The remaining contacts have a 2200 VAC test
voltage. All coaxials have 1000 VAC rms test voltage.
DPJM/DPJMB
No. of Contacts & Wire Size
Test Voltage AC (RMS)
10
9
8
7
21
20
19
18
6
5
11
17
16
4
3
2
1
15
14
13
12
C21*
21 COAX (#1-21)
1000
13
12
11
10
49
48
47
46
8 7 6 5 43 2 1
9
23 22 21 20 19 18 17 16 15 14
34 33 32 31 30 29 28 27 26 25 24
45
44 43 42 41 40 39 38 37 36 35
59 58 57 56 55 54 53 52 51 50
59
49 #20 (1-8,14-44 & 50-59)
1500
10 #12 (9-13 & 45-49)
1500
No. of Contacts & Wire Size
Test Voltage AC (RMS)
13
12
11
10
49
48
47
46
9
8 7 6 5 43 2 1
23 22 21 20 19 18 17 16 15 14
34 33 32 31 30 29 28 27 26 25 24
45
44 43 42 41 40 39 38 37 36 35
59 58 57 56 55 54 53 52 51 50
59C10*
49 #20 (1-8, 14-44&50-59)
1700
10 COAX (9-13&45-49)
1000
16 15 14 13 12 11 10 9
8 7 6 5 43 2 1
36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41 40 39 38 37
77 76 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58
98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78
98*†
98 #20 (1-98)
1500
* All DPJM and DPJMB power contact arrangements have a 1500 VAC rms test volstage. Coaxials have 1000 VAC rms voltage.
†* Available with LITTLE CAESAR contact assembly (DPJMB).
Current Carrying
Capacity of
Wires and Cables
Wire Size
Amperage
#4
80
#8
46
#12
23
#16
13
#20
7.5
Dimensions are shown in inches (millimeters).
Dimensions subject to change.
www.ittcannon.com
98