English
Language : 

MB86960 Datasheet, PDF (50/65 Pages) Fujitsu Component Limited. – NETWORK INTERFACE CONTROLLER with ENCODER/DECODER (NICE)
MB86960
DREQ
DACK
RD or WE
EOP
t1
t2
t3
Figure 21. Burst DMA Terminated by EOP
Table 25. Burst DMA Terminated by EOP
Symbol
Parameter Description
Min.
t1
EOP low to DREQ low
4
t2
EOP high to DACK high
3
t3
RD or WE low to EOP low
0
Note: EOP can be asserted during any transfer of the burst to terminate the process following that transfer.
Max.
28
Units
ns
ns
ns