English
Language : 

MC68HC908QL4 Datasheet, PDF (208/226 Pages) Motorola, Inc – Microcontrollers
Electrical Specifications
Characteristic(1)
Input hysteresis(3)
DC injection current(3) (4) (5) (6)
Single pin limit
Vin > VDD
Vin < VSS
Total MCU limit, includes sum of all stressed pins
Vin > VDD
Vin < VSS
Symbol
VHYS
Min
0.06 x VDD
Typ(2)
—
Max
—
Unit
V
0
—
2
IIC
0
—
–0.2
mA
0
—
25
0
—
–5
Ports Hi-Z leakage current
Capacitance
Ports (as input)(3)
IIL
0
—
±1
μA
CIN
—
—
8
pF
POR rearm voltage
POR rise time ramp rate(3)(7)
Monitor mode entry voltage (3)
Pullup resistors(8)
PTA0–PTA5, PTB0–PTB7
Pulldown resistors(9)
PTA0–PTA5
VPOR
RPOR
VTST
RPU
RPD
0.75
0.035
VDD + 2.5
16
16
—
—
V
—
—
V/ms
—
VDD + 4.0
V
26
36
kΩ
26
36
kΩ
Low-voltage inhibit reset, trip falling voltage
Low-voltage inhibit reset, trip rising voltage
Low-voltage inhibit reset/recover hysteresis
VTRIPF
2.65
2.8
3.0
V
VTRIPR
2.75
2.9
3.10
V
VHYS
—
100
—
mV
1. VDD = 3.0 to 3.6 Vdc, VSS = 0 Vdc, TA = TL to TH, unless otherwise noted.
2. Typical values reflect average measurements at midpoint of voltage range, 25°C only.
3. This parameter is characterized and not tested on each device.
4. All functional non-supply pins are internally clamped to VSS and VDD.
5. Input must be current limited to the value specified. To determine the value of the required current-limiting resistor,
calculate resistance values for positive and negative clamp voltages, then use the larger of the two values.
6. Power supply must maintain regulation within operating VDD range during instantaneous and operating maximum current
conditions. If positive injection current (Vin > VDD) is greater than IDD, the injection current may flow out of VDD and could
result in external power supply going out of regulation. Ensure external VDD load will shunt current greater than maximum
injection current. This will be the greatest risk when the MCU is not consuming power. Examples are: if no system clock
is present, or if clock rate is very low (which would reduce overall power consumption).
7. If minimum VDD is not reached before the internal POR reset is released, the LVI will hold the part in reset until minimum
VDD is reached.
8. RPU is measured at VDD = 3.3 V. Pullup resistors only available when PTAPUEx is enabled with KBIPx = 0.
9. RPD is measured at VDD = 3.3 V, Pulldown resistors only available when PTAPUEx is enabled with KBIPx =1.
MC68HC908QL4 Data Sheet, Rev. 7
208