English
Language : 

MC68HC000RC12 Datasheet, PDF (110/189 Pages) Freescale Semiconductor, Inc – 8-/16-/32-Bit Microprocessors User’s Manual
Freescale Semiconductor, Inc.
shown in the previously described format. The number of clock periods, the number of
read cycles, and the number of write cycles, respectively, must be added to those of the
effective address calculation where indicated by a plus sign (+).
In Table 7-6, the following notation applies:
# — Immediate operand
Dn — Data register operand
An — Address register operand
M — Memory operand
Table 7-6. Immediate Instruction Execution Times
Instruction
ADDI
Size
Byte
Word
Long
ADDQ
Byte
Word
Long
ANDI
Byte
Word
Long
CMPI
Byte
Word
Long
EORI
Byte
Word
Long
MOVEQ
Long
ORI
Byte
Word
Long
SUBI
Byte
Word
Long
SUBQ
Byte
Word
Long
+Add effective address calculation time.
op #, Dn
16(4/0)
16(4/0)
28(6/0)
8(2/0)
8(2/0)
12(2/0)
16(4/0)
16(4/0)
28(6/0)
16(4/0)
16(4/0)
26(6/0)
16(4/0)
16(4/0)
28(6/0)
8(2/0)
16(4/0)
16(4/0)
28(6/0)
16(4/0)
16(4/0)
28(6/0)
8(2/0)
8(2/0)
12(2/0)
op #, An
—
—
—
—
12(2/0)
12(2/0)
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
12(2/0)
12(2/0)
op #, M
20(4/1)+
24(4/2)+
40(6/4)+
12(2/1)+
16(2/2)+
24(2/4)+
20(4/1)+
24(4/2)+
40(6/4)+
16(4/0)
16(4/0)
24(6/0)
20(4/1)+
24(4/2)+
40(6/4)+
—
20(4/1)+
24(4/2)+
40(6/4)+
12(2/1)+
16(2/2)+
24(2/4)+
20(4/1)+
24(4/2)+
40(6/4)+
7.5 SINGLE OPERAND INSTRUCTION EXECUTION TIMES
Table 7-7 lists the timing data for the single operand instructions. The total number of
clock periods, the number of read cycles, and the number of write cycles are shown in the
previously described format. The number of clock periods, the number of read cycles, and
the number of write cycles, respectively, must be added to those of the effective address
calculation where indicated by a plus sign (+).
MOTOROLA
M68000 8-/16-/32-BIT MICROPROCESSORS USER'S MANUAL
7-5
For More Information On This Product,
Go to: www.freescale.com