MIL-DTL-5015 Crimp Rear Release
Class Descriptions, Performance Specifications
Amphenol
Aerospace
CLASS DESCRIPTIONS
Class L*
Class W
Class LS
Class KT**
Class KS
Military MIL-DTL-5015
Aluminum shell, electroless nickel finish,
fluid resistant insert
Aluminum shell, cadmium olive drab finish,
fluid resistant insert
Stainless steel shell, passivated, fluid
resistant insert
Firewall, steel shell, cadmium olive drab finish,
non-flammable hard dielectric and fluid resistant insert
Firewall, stainless steel shell, passivated,
non-flamma­ble hard dielectric and fluid resistant insert
  * Class L inactivates older Class U (aluminum, electroless nickel)
** Class KT (ferrous alloy, cadmium/olive drab) inactivates older Class K
(ferrous alloy, electroless nickel)
Class A
Class F
Class W
Class FS
Class KT
Class KS
Amphenol/Matrix
Aluminum shell, black anodize finish,
fluid resistant insert
Aluminum shell, electroless nickel finish,
fluid resistant insert
Aluminum shell, cadmium/olive drab finish,
fluid resistant insert
Stainless steel shell, passivated, fluid resistant insert
Firewall, steel shell, cadmium olive drab finish,
non-flammable hard dielectric and fluid resistant insert
Firewall, stainless steel shell, passivated,
non-flammab­ le hard dielectric and fluid resistant insert
PERFORMANCE SPECIFICATIONS
VOLTAGE RATING
Altitude
Sea Level
50,000 ft.
70,000 ft.
110,000 ft.
Inst.
1000
400
260
200
A
2000
600
360
200
D
2800
675
400
200
E
3500
750
440
200
B
4500
825
480
200
C
7000
975
560
200
SHOCK
Wired, mated connectors are subjected to one shock in each of three mutu­ally
perpendicular axes with pulse of an approximate half sine wave of 50g magnitude for a
duration of 11 milliseconds. All contacts wired in series cir­cuit with 100 ±10 Milliamperes
of current flow.
OPERATING TEMPERATURE RANGE
Classes L, LS and KS have temperature range of
–55°C (–75°F) to 200°C (392°F)
Classes W and KT have temperature range of
–55°C (–75°F) to 175°C (347°F)
ENVIRONMENTAL SEAL
Wired, mated connectors with the specified accessory attached will meet the
altitude immersion test specified in MIL-DTL-5015.
DURABILITY
Minimum of 100 mating cycles.
Contact Amphenol Aerospace for more information at 800-678-0141•www.amphenol-aerospace.com 183