English
Language : 

Z8S18020FSC Datasheet, PDF (23/70 Pages) Zilog, Inc. – ENHANCED Z180 MICROPROCESSOR
Zilog
STANDARD TEST CONDITIONS
The DC Characteristics and Capacitance sections above
apply to the following standard test conditions, unless oth-
erwise noted. All voltages are referenced to GND (0V).
Positive current flows in to the referenced pin.
All AC parameters assume a load capacitance of 100 pF.
Add 10 ns delay for each 50 pF increase in load up to a
maximum of 200 pF for the data bus and 100 pF for the ad-
dress and control lines. AC timing measurements are ref-
erenced to 1.5 volts (except for CLOCK, which is refer-
enced to the 10% and 90% points). The Ordering
Information section lists temperature ranges and product
numbers. Package drawings are in the Package Informa-
tion section. Refer to the Literature List for additional doc-
umentation.
ABSOLUTE MAXIMUM RATINGS
Item
Supply Voltage
Input Voltage
Operating Temperature
Extended Temperature
Storage Temperature
Symbol
Vcc
Vin
Topr
Text
Tstg
Note: Permanent LSI damage may occur if maximum
ratings are exceeded. Normal operation should be under
recommended operating conditions. If these conditions
are exceeded, it could affect reliability of LSI.
Z80180/Z8S180/Z8L180
Enhanced Z180 Microprocessor
From Output
Under Test
+5 V
1
2.1k
100 pF
250
µA
Figure 19. AC Load Capacitance Parameters
Value
Unit
-0.3 ~ +7.0
V
-0.3 ~ Vcc +0.3
V
0 ~ 70
°C
-40 ~ 85
°C
-55 ~ +150
°C
DS971800401
PRELIMINARY
1-23