Virtex UltraScale FPGAs Data Sheet: DC and AC Switching Characteristics
Table 3: DC Characteristics Over Recommended Operating Conditions
Symbol
Description
Min
Typ(1)
Max Units
VDRINT
Data retention VCCINT voltage (below which configuration
data might be lost).
0.82
â
â
V
VDRAUX
Data retention VCCAUX voltage (below which configuration
data might be lost).
1.50
â
â
V
IREF
IL
CIN(3)
VREF leakage current per pin.
â
Input or output leakage current per pin (sample-tested).
â
Die input capacitance at the pad (HP I/O).
â
Die input capacitance at the pad (HR I/O).
â
â
15
µA
â
15(2)
µA
â
3.75
pF
â
7.00
pF
IRPU
IRPD
ICCADC
Pad pull-up (when selected) at VIN = 0V, VCCO = 3.3V.
Pad pull-up (when selected) at VIN = 0V, VCCO = 2.5V.
Pad pull-up (when selected) at VIN = 0V, VCCO = 1.8V.
Pad pull-up (when selected) at VIN = 0V, VCCO = 1.5V.
Pad pull-up (when selected) at VIN = 0V, VCCO = 1.2V.
Pad pull-down (when selected) at VIN = 3.3V.
Pad pull-down (when selected) at VIN = 1.8V.
Analog supply current, per SYSMON instance, in the
powered up state.
75
â
175
µA
50
â
169
µA
60
â
678
µA
30
â
450
µA
10
â
262
µA
60
â
190
µA
29
â
685
µA
â
â
19.2
mA
IBATT(4)
Battery supply current.
â
â
150
nA
Calibrated programmable on-die termination (DCI) in HP I/O banks(6) (measured per JEDEC specification).
Thevenin equivalent resistance of programmable input
termination to VCCO/2 where ODT = RTT_40.
â10%(5)
40
+10%(5) Ω
Thevenin equivalent resistance of programmable input
termination to VCCO/2 where ODT = RTT_48.
â10%(5)
48
+10%(5) Ω
Thevenin equivalent resistance of programmable input
termination to VCCO/2 where ODT = RTT_60.
â10%(5)
60
+10%(5) Ω
R(7)
Programmable input termination to VCCO where
ODT = RTT_40.
â10%(5)
40
+10%(5) Ω
Programmable input termination to VCCO where
ODT = RTT_48.
â10%(5)
48
+10%(5) Ω
Programmable input termination to VCCO where
ODT = RTT_60.
â10%(5)
60
+10%(5) Ω
Programmable input termination to VCCO where
ODT = RTT_120.
â10%(5)
120 +10%(5) Ω
Programmable input termination to VCCO where
ODT = RTT_240.
â10%(5)
240 +10%(5) Ω
DS893 (v1.7.1) April 4, 2016
Product Specification
www.xilinx.com
Send Feedback