English
Language : 

W83L517D_05 Datasheet, PDF (96/133 Pages) Winbond – LPC I/O for Notebook
W83L517D/W83L517D-F
9.3 Extended Capabilities Parallel (ECP) Port
This port is software and hardware compatible with existing parallel ports, so it may be used as a
standard printer mode if ECP is not required. It provides an automatic high burst-bandwidth channel
that supports DMA for ECP in both the forward (host to peripheral) and reverse (peripheral to host)
directions.
Small FIFOs are used in both forward and reverse directions to improve the maximum bandwidth
requirement. The size of the FIFO is 16 bytes. The ECP port supports an automatic handshake for the
standard parallel port to improve compatibility mode transfer speed.
The ECP port supports run-length-encoded (RLE) decompression (required) in hardware.
Compression is accomplished by counting identical bytes and transmitting an RLE byte that indicates
how many times the next byte is to be repeated. Hardware support for compression is optional.
For more information about the ECP Protocol, refer to the Extended Capabilities Port Protocol and ISA
Interface Standard.
9.3.1 ECP Register and Mode Definitions
NAME
data
ecpAFifo
dsr
dcr
cFifo
ecpDFifo
tFifo
cnfgA
cnfgB
ecr
ADDRESS
Base+000h
Base+000h
Base+001h
Base+002h
Base+400h
Base+400h
Base+400h
Base+400h
Base+401h
Base+402h
I/O
R/W
R/W
R
R/W
R/W
R/W
R/W
R
R/W
R/W
ECP MODES
000-001
011
All
All
010
011
110
111
111
All
FUNCTION
Data Register
ECP FIFO (Address)
Status Register
Control Register
Parallel Port Data FIFO
ECP FIFO (DATA)
Test FIFO
Configuration Register A
Configuration Register B
Extended Control Register
Note: The base addresses are specified by CR23, which are determined by configuration register or hardware setting.
MODE
DESCRIPTION
000 SPP mode
001 PS/2 Parallel Port mode
010 Parallel Port Data FIFO mode
011 ECP Parallel Port mode
100 EPP mode (If this option is enabled in the CR9 and CR0 to select ECP/EPP mode)
101 Reserved
110 Test mode
111 Configuration mode
Note: The mode selection bits are bit 7-5 of the Extended Control Register.
- 96 -