English
Language : 

W83L517D_05 Datasheet, PDF (27/133 Pages) Winbond – LPC I/O for Notebook
W83L517D/W83L517D-F
(3) Read A Track
PHASE R/W
Command W
W
W
W
W
W
W
W
W
Execution
Result
R
R
R
R
R
R
R
D7 D6 D5 D4 D3 D2 D1 D0
0 MFM 0 0 0 0 1 0
0 0 0 0 0 HDS DS1 DS0
---------------------- C ------------------------
---------------------- H ------------------------
---------------------- R ------------------------
---------------------- N ------------------------
-------------------- EOT -----------------------
-------------------- GPL -----------------------
-------------------- DTL -----------------------
-------------------- ST0 -----------------------
-------------------- ST1 -----------------------
-------------------- ST2 -----------------------
---------------------- C ------------------------
---------------------- H ------------------------
---------------------- R ------------------------
---------------------- N ------------------------
REMARKS
Command codes
Sector ID information prior
to command execution
Data transfer between the
FDD and system; FDD
reads contents of all
cylinders from index hole to
EOT
Status information after
command execution
Sector ID information after
command execution
- 27 -
Publication Release Date: May 23, 2005
Revision 1.0