W83977F Datasheet, PDF (164/181 Pages) Winbond – PLUG & PLAY 1.0A COMPLIANT | |||
|
◁ |
11.3.9 KBC Timing Parameters
W83977F/ W83977AF
PRELIMINARY
NO.
DESCRIPTION
MIN.
MAX.
UNIT
T1
Address Setup Time from WRB
0
nS
T2
Address Setup Time from RDB
0
nS
T3
WRB Strobe Width
20
nS
T4
RDB Strobe Width
20
nS
T5
Address Hold Time from WRB
0
nS
T6
Address Hold Time from RDB
0
nS
T7
Data Setup Time
50
nS
T8
Data Hold Time
0
nS
T9
Gate Delay Time from WRB
10
30
nS
T10 RDB to Drive Data Delay
40
nS
T11 RDB to Floating Data Delay
0
20
nS
T12 Data Valid After Clock Falling (SEND)
4
µS
T13 K/B Clock Period
20
µS
T14 K/B Clock Pulse Width
10
µS
T15 Data Valid Before Clock Falling (RECEIVE)
4
µS
T16 K/B ACK After Finish Receiving
20
µS
T17 RC Fast Reset Pulse Delay (8 Mhz)
2
3
µS
T18 RC Pulse Width (8 Mhz)
6
µS
T19 Transmit Timeout
2
mS
T20 Data Valid Hold Time
0
µS
T21 Input Clock Period (6â12 Mhz)
83
167
nS
T22 Duration of CLK inactive
30
50
µS
T23 Duration of CLK active
30
50
µS
T24 Time from inactive CLK transition, used to time when
5
the auxiliary device sample DATA
25
µS
T25 Time of inhibit mode
100
300
µS
T26 Time from rising edge of CLK to DATA transition
5
T28-5
µS
T27 Duration of CLK inactive
30
50
µS
T28 Duration of CLK active
30
50
µS
T29 Time from DATA transition to falling edge of CLK
5
25
µS
- 152 -
Publication Release Date: March 1998
Revision 0.58
|
▷ |