Bit/Field
2
1
0
Name
LINK
JAB
EXTD
Type
RO
RC
RO
Reset
0
0
1
Description
Link Made
When set, this bit indicates that a valid link has been established by the
Ethernet Controller.
Jabber Condition
When set, this bit indicates that a jabber condition has been detected
by the Ethernet Controller. This bit remains set until it is read, even if
the jabber condition no longer exists.
Extended Capabilities
When set, this bit indicates that the Ethernet Controller provides an
extended set of capabilities that can be accessed through the extended
register set.
July 16, 2014
535