System Control
■ Crystal input selection
Important: Write the RCC register prior to writing the RCC2 register. If a subsequent write to the
RCC register is required, include another register access after writing the RCC register
and before writing the RCC2 register.
Figure 5-5 shows the logic for the main clock tree. The peripheral blocks are driven by the system
clock signal and can be individually enabled/disabled. When the PLL is enabled, the ADC clock
signal is automatically divided down to 16 MHz from the PLL output for proper ADC operation.
Note: When the ADC module is in operation, the system clock must be at least 16 MHz.