English
Language : 

GC5018 Datasheet, PDF (113/115 Pages) Texas Instruments – 8-CHANNEL WIDEBAND RECEIVER
www.ti.com
GC5018
8-CHANNEL WIDEBAND RECEIVER
SLWS169 – MAY 2005
–40°C to 85°C case supplies across recommended range (unless otherwise noted)
tEWCSU
tCHD
tCSPW
tCDLY
tREC
tHIZ
tCOH
ICDYN
PARAMETER
Control setup during writes
3 pin mode: d[15:0] valid before wr_n and ce_n rising edge
2 pin mode: d[15:0] valid before ce_n rising edge (1)
Control hold during writes.
3 pin mode: a[5:0] and d[15:0] valid after wr_n and ce_n rise
2 pin mode: a[5:0], d[15:0] and wr_n valid after ce_n rise (1)
Control strobe (ce_n and wr_n low) pulse width during write. (1)
Control output delay ce_n and rd_n low and a[5:0] stable to d[15:0] during read. (1)
Control recovery time between reads or writes. (1)
Control end of read to Hi-Z. rd_n and ce_n rise to d[15:0] 3-state (1)
Control read d[15:0] output hold time(1)
Core dynamic supply current ,nominal voltages, 160 MHz, (specific conditions, typical app with chip busy
within capability of the tester, high temperature.)(1)
MIN MAX UNIT
10
ns
6
ns
15
ns
25 ns
6 ns
10 ns
3
ns
1700 mA