English
Language : 

CLRC663 Datasheet, PDF (72/132 Pages) NXP Semiconductors – Contactless reader IC
NXP Semiconductors
CLRC663
Contactless reader IC
Table 72. RxBitCtrl bits
Bit
Symbol
Description
6 to 4 RxAlign
Used for reception of bit oriented frames: RxAlign defines the bit position
length for the first bit received to be stored. Further received bits are
stored at the following bit positions.
Example:
RxAlign = 0h - the LSB of the received bit is stored at bit 0, the second
received bit is stored at bit position 1.
RxAlign = 1h - the LSB of the received bit is stored at bit 1, the second
received bit is stored at bit position 2.
RxAlign = 7h - the LSB of the received bit is stored at bit 7, the second
received bit is stored in the following byte at position 0.
Note: If RxAlign = 0, data is received byte-oriented, otherwise
bit-oriented.
3
NoColl
If this bit is set, a collision will result in an IntegErr
2 to 0
RxLastBits Defines the number of valid bits of the last data byte received in
bit-oriented communications. If zero the whole byte is valid.
Note: These bits are set by the RxDecoder in a bit-oriented
communication at the end of the communication. They are reset at start
of reception.
CLRC663
Product data sheet
COMPANY PUBLIC
All information provided in this document is subject to legal disclaimers.
Rev. 3.3 — 3 April 2012
171133
© NXP B.V. 2012. All rights reserved.
72 of 132