English
Language : 

CLRC663 Datasheet, PDF (110/132 Pages) NXP Semiconductors – Contactless reader IC
NXP Semiconductors
CLRC663
Contactless reader IC
9.16.13 TxSym32Mod
Table 223. TxSym32Mod register (address 57h)
Bit
7
6
5
4
Symbol
RFU S32MillerEn
S32PulseType
Access
-
r/w
r/w
rights
3
S32Invert
r/w
2
1
0
S32EnvType
r/w
Table 224. TxSym32Mod bits
Bit
Symbol
Description
7
RFU
-
6
S32MillerEn If set, pulse modulation is applied according to modified miller code.
Note: This bit shall be set only if S32PulseType is set to 1h
5 to 4 S32PulseType Specifies which type of pulse modulation is selected.
0h - no pulse modulation
1h - pulse starts at beginning of bit
2h - pulse starts at beginning of second bit half
3h - pulse starts at beginning of third bit quarter
3
S32Inv
If set. the output of Symbol2 and Symbol3 is inverted.
2 to 0
S32EnvType
Specifies the type of envelope used for transmission of symbol 0 and
symbol 1. The bit stream is logically combined with the selected
envelope type.
0h - Direct output
1h - Manchester code
2h - Manchester code with subcarrier
3h - BPSK
4h - RZ return zero, pulse of half bit length at beginning of second half
of bit)
5h - RZ return zero, pulse of half bit length at beginning of bit)
6h to 7h RFU
9.17 Receiver configuration
9.17.1 RxBitMod
Table 225. RxBitMod (address 58h)
Bit
7
6
5
Symbol RFU RFU RxStopOnInvPar
Access -
-
r/w
rights
4
RxStopOnLength
r/w
3
RxMSBFirst
r/w
2
RxStopBitEn
r/w
1
RxParityType
r/w
0
RFU
-
CLRC663
Product data sheet
COMPANY PUBLIC
All information provided in this document is subject to legal disclaimers.
Rev. 3.3 — 3 April 2012
171133
© NXP B.V. 2012. All rights reserved.
110 of 132