English
Language : 

CLRC663 Datasheet, PDF (34/132 Pages) NXP Semiconductors – Contactless reader IC
NXP Semiconductors
CLRC663
Contactless reader IC
8.4.6.10 Non-IEEE1149.1 commands
Interface on/off: With this command the host/SAM interface can be deactivated and the
Read and Write command of the boundary scan interface is activated. (Data = 1). With
Update-DR the value is taken over.
Register Access Read: At Capture-DR the actual address is read and stored in the DR.
Shifting the DR is shifting in a new address. With Update-DR this address is taken over
into the actual address.
CLRC663
Product data sheet
COMPANY PUBLIC
All information provided in this document is subject to legal disclaimers.
Rev. 3.3 — 3 April 2012
171133
© NXP B.V. 2012. All rights reserved.
34 of 132