English
Language : 

CLRC663 Datasheet, PDF (48/132 Pages) NXP Semiconductors – Contactless reader IC
NXP Semiconductors
CLRC663
Contactless reader IC
Table 36. Interface bits
Bit
Symbol
Description
7
I2C_HSP
when cleared, the high speed mode is used
when set, the high speed+ mode is used (default)
6, 5
RFU
-
4
I2C_Address when cleared, the pins are used (default)
when set, the EEPROM is used
3
Boundary
when cleared, the boundary scan interface is ON (default)
Scan
when set, the boundary scan is OFF
2 to 0 Host
000b - RS232
001b - I2C
010b - SPI
011b - I2CL
1xxb - pin selection
I2C_SAM_Address: The I2C SAM Address is always defined by the EEPROM content.
: The Register Set Protocol (RSP) Area contains settings for the TX registers (16 bytes)
and for the RX registers (8 bytes).
Table 37. Tx and Rx arrangements in the register set protocol area
Section
Section 4 TX Tx0
Tx1
TX2
Section 4 TX Tx4
Tx5
TX6
Section 4 Rx RX0
RX1
RX2
RX3
RX4
RX5
Section 4 Rx RX8
RX9 RX10 RX11 RX12 RX13
Tx3
TX7
RX6
RX14
RX7
RX15
TxCrcPreset: The data bits send by the analog module of the are automatically extended
by a CRC.
8.7.3 EEPROM initialization content LoadProtocol
The CLRC663 EEPROM is initialized at production with default values which are used to
reset the registers of the CLRC663 by copying the EEprom content to the registers. Note
that the addresses used for copying reset values from EEprom to registers are dependent
on the configured protocol and can be changed by the user.
Table 38. Register reset values (Hex.) (Page0)
Address 0
1
2
3
4
5
6
7
Function Product ID
Version
Factory trim values
00
00
01
01
XX
XX
XX
XX
XX
Function Factory trim values
08
XX
XX
XX
XX
XX
XX
XX
XX
Function TrimLPO Factory trim values
10
XX
XX
XX
XX
XX
XX
XX
XX
CLRC663
Product data sheet
COMPANY PUBLIC
All information provided in this document is subject to legal disclaimers.
Rev. 3.3 — 3 April 2012
171133
© NXP B.V. 2012. All rights reserved.
48 of 132