English
Language : 

CLRC663 Datasheet, PDF (56/132 Pages) NXP Semiconductors – Contactless reader IC
NXP Semiconductors
CLRC663
Contactless reader IC
This command does not terminate automatically, when the card does not answer,
therefore the timer should be initialized to automatic mode. In this case, beside the bit
IdleIRq the bit TimerIRq can be used as termination criteria. During authentication
processing the bits RxIRq and TxIRq are blocked. The Crypto1On shows if the
authentication was successful.
The following data shall be written to the FIFO before the command can be activated:
• Authentication command code (60h, 61h)
• Block address
• Card serial number byte 0
• Card serial number byte 1
• Card serial number byte 2
• Card serial number byte 3
In total, 6 bytes are written to the FIFO.
Remark: When the MFAuthent command is active, any FIFO access is blocked. If there is
an attempt to access to the FIFO during MFAuthent being active, the bit WrErr in the Error
register is set.
This MFAuthent command terminates automatically when the MIFARE card is
authenticated and the bit MFCrypto1On in the Status register is set to logic 1.
This MFAuthent command does not terminate automatically when the card does not
answer, therefore the timer should be initialized to automatic mode. In this case, beside
the bit IdleIrq, the bit TimerIrq can be used as termination criteria. During authentication
processing the bit RxIrq and bit TxIrq are blocked. The Crypto1On bit is only valid after
termination of the authentication command (either after processing the protocol or after
writing IDLE to the command register).
In case there is an error during authentication, the bit ProtocolErr in the Error register is
set to logic 1 and the bit Crypto1On in register Status2Reg is set to logic 0.
8.10.3.5 AckReq command
Command (04h);
Performs a Query (Full command must be written into the FIFO); a Ack and a ReqRn
command. All answers to the command will be written into the FIFO. The error flag is
copied after the answer into the FIFO.
This command terminates automatically when finished and the active command is idle.
8.10.3.6 Receive command
Command (05h);
The CLRC663 activates the receiver path and waits for any data stream to be received.
The correct settings have to be chosen before starting this command.
This command terminates automatically when the received data stream ends. This is
indicated either by the end of frame pattern or by the length byte depending on the
selected framing and speed.
CLRC663
Product data sheet
COMPANY PUBLIC
All information provided in this document is subject to legal disclaimers.
Rev. 3.3 — 3 April 2012
171133
© NXP B.V. 2012. All rights reserved.
56 of 132