TLE94106EL Datasheet, PDF (67/75 Pages) Infineon Technologies AG – Six half bridge power outputs
TLE94106EL
Serial Peripheral Interface (SPI)
SYS_DIAG_6 : OP_ERROR_5_STAT
Open load error status of half-bridge outputs 5 - 8 (Address Byte [OP]100 01[LABT]1B)
D7
D6
D5
D4
D3
D2
D1
D0
reserved
rc
reserved
rc
reserved
rc
reserved
rc
HB6_HS_OL HB6_LS_OL HB5_HS_OL HB5_LS_OL
r
rc
rc
rc
rc
Field
Bits
reserved D7
reserved D6
reserved D5
reserved D4
HB6_HS_OL D3
HB6_LS_OL D2
HB5_HS_OL D1
HB5_LS_OL D0
Type
rc
rc
rc
rc
rc
rc
rc
rc
Description
Reserved. Always reads as ‘0’.
Reserved. Always reads as ‘0’.
Reserved. Always reads as ‘0’.
Reserved. Always reads as ‘0’.
High-side (HS) switch of half-bridge 6 open load detection
0B No error on HS6 switch (default value)
1B Open load detected on HS6 switch. Error latched.
Low-side (LS) switch of half-bridge 6 open load detection
0B No error on LS6 switch (default value)
1B Open load detected on LS6 switch. Error latched.
High-side (HS) switch of half-bridge 5 open load detection
0B No error on HS5 switch (default value)
1B Open load detected on HS5 switch. Error latched.
Low-side (LS) switch of half-bridge 5 open load detection
0B No error on LS5 switch (default value)
1B Open load detected on LS5 switch. Error latched.
Data Sheet
67
1.0