English
Language : 

TLE94106EL Datasheet, PDF (66/75 Pages) Infineon Technologies AG – Six half bridge power outputs
TLE94106EL
Serial Peripheral Interface (SPI)
SYS_DIAG_5 : OP_ERROR_4_STAT
Open load error status of half-bridge outputs 1 - 4 (Address Byte [OP]000 01[LABT]1B)
D7
D6
D5
D4
D3
D2
D1
D0
HB4_HS_OL HB4_LS_OL HB3_HS_OL HB3_LS_OL HB2_HS_OL HB2_LS_OL HB1_HS_OL HB1_LS_OL
r
rc
rc
rc
rc
rc
rc
rc
rc
Field
Bits
HB4_HS_OL D7
HB4_LS_OL D6
HB3_HS_OL D5
HB3_LS_OL D4
HB2_HS_OL D3
HB2_LS_OL D2
HB1_HS_OL D1
HB1_LS_OL D0
Type
rc
rc
rc
rc
rc
rc
rc
rc
Description
High-side (HS) switch of half-bridge 4 open load detection
0B No error on HS4 switch (default value)
1B Open load detected on HS4 switch. Error latched.
Low-side (LS) switch of half-bridge 4 open load detection
0B No error on LS4 switch (default value)
1B Open load detected on LS4 switch. Error latched.
High-side (HS) switch of half-bridge 3 open load detection
0B No error on HS3 switch (default value)
1B Open load detected on HS3 switch. Error latched.
Low-side (LS) switch of half-bridge 3 open load detection
0B No error on LS3 switch (default value)
1B Open load detected on LS3 switch. Error latched.
High-side (HS) switch of half-bridge 2 open load detection
0B No error on HS2 switch (default value)
1B Open load detected on HS2 switch. Error latched.
Low-side (LS) switch of half-bridge 2 open load detection
0B No error on LS2 switch (default value)
1B Open load detected on LS2 switch. Error latched.
High-side (HS) switch of half-bridge 1 open load detection
0B No error on HS1 switch (default value)
1B Open load detected on HS1 switch. Error latched.
Low-side (LS) switch of half-bridge 1 open load detection
0B No error on LS1 switch (default value)
1B Open load detected on LS1 switch. Error latched.
Data Sheet
66
1.0
2016-09-08