English
Language : 

TLE94106EL Datasheet, PDF (54/75 Pages) Infineon Technologies AG – Six half bridge power outputs
TLE94106EL
Serial Peripheral Interface (SPI)
HB_ACT_2_CTRL
Half-bridge output control 2 (Address Byte [OP]100 00[LABT]1B)
D7
D6
D5
D4
D3
D2
D1
D0
reserved
rw
reserved
rw
reserved
rw
reserved HB6_HS_EN HB6_LS_EN HB5_HS_EN HB5_LS_EN
r
rw
rw
rw
rw
rw
Field
Bits
reserved D7
reserved D6
reserved D5
reserved D4
HB6_HS_EN D3
HB6_LS_EN D2
HB5_HS_EN D1
HB5_LS_EN D0
Type
rw
rw
rw
rw
rw
rw
rw
rw
Description
Reserved. Always reads as ‘0’
Reserved. Always reads as ‘0’
Reserved. Always reads as ‘0’
Reserved. Always reads as ‘0’
Half-bridge output 6 high side switch enable
0B HS6 OFF/ High-Z (default value)
1B HS6 ON
Half-bridge output 6 low side switch enable
0B LS6 OFF/ High-Z (default value)
1B LS6 ON
Half-bridge output 5 high side switch enable
0B HS5 OFF/ High-Z (default value)
1B HS5 ON
Half-bridge output 5 low side switch enable
0B LS5 OFF/ High-Z (default value)
1B LS5 ON
Note:
The simultaneous activation of both HS and LS switch within a half-bridge is prevented by the
digital block to avoid cross current. If both LS_EN and HS_EN bits of a given half-bridge are set, the
logic turns off this half-bridge.
Data Sheet
54
1.0
2016-09-08