English
Language : 

TLE94106EL Datasheet, PDF (65/75 Pages) Infineon Technologies AG – Six half bridge power outputs
TLE94106EL
Serial Peripheral Interface (SPI)
SYS_DIAG_3 : OP_ERROR_2_STAT
Overcurrent error status of half-bridge outputs 5 - 8 (Address Byte [OP]011 10[LABT]1B)
D7
D6
D5
D4
D3
D2
D1
D0
reserved
rc
reserved
rc
reserved
rc
reserved HB6_HS_OC HB6_LS_OC HB5_HS_OC HB5_LS_OC
r
rc
rc
rc
rc
rc
Field
Bits
reserved D7
reserved D6
reserved D5
reserved D4
HB6_HS_OC D3
HB6_LS_OC D2
HB5_HS_OC D1
HB5_LS_OC D0
Type
rc
rc
rc
rc
rc
rc
rc
rc
Description
Reserved. Always reads as ‘0’.
Reserved. Always reads as ‘0’.
Reserved. Always reads as ‘0’.
Reserved. Always reads as ‘0’.
High-side (HS) switch of half-bridge 6 overcurrent detection
0B No error on HS6 switch (default value)
1B Overcurrent detected on HS6 switch. Error latched and HS6
disabled.
Low-side (LS) switch of half-bridge 6 overcurrent detection
0B No error on LS6 switch (default value)
1B Overcurrent detected on LS6 switch. Error latched and LS6
disabled.
High-side (HS) switch of half-bridge 5 overcurrent detection
0B No error on HS5 switch (default value)
1B Overcurrent detected on HS5 switch. Error latched and HS5
disabled.
Low-side (LS) switch of half-bridge 5 overcurrent detection
0B No error on LS5 switch (default value)
1B Overcurrent detected on LS5 switch. Error latched and LS5
disabled.
Data Sheet
65
1.0
2016-09-08