36. Timing Parameters
Timing Parameters Summary
Para- Description
meter
-C80
-45
tRC Row Cycle time of RDRAM banks - the interval between ROWA packets 28
with ACT commands to the same bank.
tRAS RAS-asserted time of RDRAM bank - the interval between ROWA packet
20
with ACT command and next ROWR packet with PRER Note 1 command to the
same bank.
tRP Row Precharge time of RDRAM banks - the interval between ROWR packet 8
with PRER Note 1 command and next ROWA packet with ACT command to the
same bank.
tPP Precharge-to-precharge time of RDRAM device - the interval between
8
successive ROWR packets with PRER Note1 commands to any banks of
the same device.
tRR RAS-to-RAS time of RDRAM device - the interval between successive
8
ROWA packets with ACT commands to any banks of the same device.
tRCD RAS-to-CAS Delay - the interval from ROWA packet with ACT
9
command to COLC packet with RD or WR command. Note - the RAS-
to-CAS delay seen by the RDRAM core (tRCD-C) is equal to tRCD-C = 1 +
tRCD because of differences in the row and column paths through the
RDRAM interface.
tCAC CAS Access delay - the interval from RD command to Q read data. The 8
equation for tCAC is given in the TPARM register in Figure 22-1(5/7).
tCWD CAS Write Delay - interval from WR command to D write data.
6
tCC CAS-to-CAS time of RDRAM bank - the interval between successive
4
COLC commands.
tPACKET Length of ROWA, ROWR, COLC, COLM or COLX packet.
4
tRTR Interval from COLC packet with WR command to COLC packet which
8
causes retire, and to COLM packet with bytemask.
tOFFP The interval (offset) from COLC packet with RDA command, or from
4
COLC packet with retire command (after WRA automatic precharge), or
from COLC packet with PREC command, or from COLX packet with
PREX command to the equivalent ROWR packet with PRER. The
equation for tOFFP is given in the TPARM register in Figure 22-1(5/7).
tRDP Interval from last COLC packet with RD command to ROWR packet
4
with PRER.
tRTP Interval from last COLC packet with automatic retire command to
4
ROWR packet with PRER.
MIN.
-C71
-45
28
20
8
8
8
7
8
6
4
4
8
4
4
4
-C60
-53
28
20
8
8
8
7
8
6
4
4
8
4
4
4
MAX. Units Figures
— tCYCLE Figure13-1
Figure14-1
Note 2 tCYCLE Figure13-1
64µs
Figure14-1
— tCYCLE Figure13-1
Figure14-1
— tCYCLE Figure10-3
— tCYCLE Figure12-1
— tCYCLE Figure13-1
Figure14-1
12 tCYCLE Figure4-1
6 tCYCLE Figure4-1
— tCYCLE Figure13-1
Figure14-1
4 tCYCLE Figure2-1
— tCYCLE Figure15-1
4 tCYCLE Figure14-2
— tCYCLE Figure13-1
— tCYCLE Figure14-1
Notes 1. Or equivalent PREC or PREX command. See Figure 12-2.
2. This is a constraint imposed by the core, and is therefore in units of ms rather than tCYCLE.
66