Default value: m = 0, (1ms)
Leak_Obs_Window, 0x08 (R/W)
STC5423
Synchronous Clock for SETS
Data sheet
Address
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
0x08
Not used
Leaky bucket leak observation window, n = 0 ~ 15
Sets the leak observation window size of the reference activity monitor to (n + 1) times the fill observation win-
dow size. The size can be set from 1 to 16ms times the fill observation window size.
Default value: n = 3,
Bucket_Size, 0x09 (R/W)
Address
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
0x09
Not used
Leaky bucket size, 0 ~ 63
Sets the leaky bucket size for the reference activity monitor. Bucket size equal to 0 will bypass the leaky bucket
accumulator, and assert or de-assert the activity alarm based on results of frequency detector and pulse moni-
tor only. The bucket size must be greater than or equal to the alarm assert value. Otherwise, the value will not
be written to the register.
Default value: 20
Assert_Threshold, 0x0A (R/W)
Address
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
0x0A
Not used
Leaky bucket alarm assert threshold, 1 ~ 63
Sets the leaky bucket alarm assert threshold for the reference activity monitor. The alarm assert threshold
value must be greater than the de-assert threshold value and less than or equal to the bucket size value. Oth-
erwise, the value will not be written to the register.
Default value: 15
De_Assert_Threshold, 0x0B (R/W)
Address
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
0x0B
Not used
Leaky bucket alarm de-assert threshold, 0 ~ 62
Sets the leaky bucket alarm de-assert threshold for the reference activity monitor. The de-assert threshold
value must be less than the assert threshold value. Otherwise, the value will not be written to the register.
Default value: 10
Page 34 of 60 TM114
Rev:1.4
© Copyright the Connor-Winfield Corp. All Rights Reserved Specifications subject to change without notice
Date: October 24, 2011