English
Language : 

AK4695 Datasheet, PDF (59/107 Pages) Asahi Kasei Microsystems – 24bit 4ch CODEC with MIC/HP/SPK/LINE-AMP
[AK4695]
(3-2) Dynamic Volume Control Curve
The inflection points of the DVLC curve is set by three coordinate values (VH1X5-0, VH1Y5-0, VH2X5-0, VH2Y5-0,
VH3X4-0 and VH3Y4-0 bits). The setting of three inflection points are calculated the values of (X1H, Y1H), (X2H, Y2HH),
(X3H, Y3H) in dB. The inflection points should be set in such a way that VH1X ≤ VH2X ≤ VH3X, VH1Y ≤ VH2Y ≤ VH3Y.
And the each slope is set by H1G6-0, H2G6-0, H3G6-0 and H4G6-0 bits. X4H is fixed full-scale, Y4H is calculated by the
H4G value. The initial value of the DVLC gain is set by the H1G.
Full scale
(X3H, Y3H)
(X2H, Y2H)
H3G
H4G
(X4H, Y4H)
(X1H, Y1H)
H2G
H1G
(0, 0)
DVLC Input Level
Full scale
Figure 39. DVLC Curve for High Frequency Range
VH1X/Y5-0 bits Dynamic Volume Control Point
VH2X/Y5-0 bits
[dB]
Step
00H
0
(default)
01H
1.5
02H
:
3.0
:
1.5dB
2EH
69.0
2FH
70.5
30H
N/A
:
:
N/A
3FH
N/A
Table 57. DVLC Point Setting for X/Y1, X/Y2 (N/A: Not available)
VH3X/Y4-0 bits
00H
01H
02H
:
1EH
1FH
Dynamic Volume Control Point
[dB]
Step
0
1.5
3.0
:
1.5dB
45.0
46.5
Table 58. DVLC Point Setting for X/Y3
(default)
MS1463-E-01
- 59 -
2014/12